Problem |
Possible Causes |
Checks & Remedies |
Sporadic Wet Foam |
Improper mixture of cleaning solution. |
Make sure the chemical is a foaming chemical. |
| Constant Wet Foam |
Wet Foam/Dry Foam valve may not be open far enough. |
Turn Wet Foam/Dry Foam valve counter-clockwise |
| Sporadic Dry Foam |
Wet Foam/Dry Foam valve may be open too far. |
Turn Wet Foam/Dry Foam valve clockwise until the pump begins to run consistently. |
| Unit Foams at Reduced Pressure |
Compressed air supply may not be adequate to run the unit. |
A larger air compressor or air line needs to be used to supply enough air to the unit. |
| Only Air Discharges from the Foam Wand. |
Wet Foam/Dry Foam valve may be open |
Turn Wet Foam/Dry Foam valve clockwise until |
Cautions• Always follow all safety and warning instructions on the chemical label and MSDS sheet for the chemical being used through the FOAM-iT unit. • Always wear safety goggles, protective gloves, and all other necessary protective clothing specified by the chemical's MSDS sheet while operating or servicing any FOAM-iT units. • Always make sure the unit is depressurized before servicing the unit. Never point the discharge wand toward anyone. • Avoid spraying in areas where water or chemical can cause damage. • After each use, turn off the air supply to the FOAM-iT unit and relieve all remaining pressure in the unit by opening the discharge ball valve. • Thoroughly flush the unit with water whenever switching from one chemical to another. For further technical assistance, email us techsupport@foamit.com or call 1-800-567-5420. |
||